In an elevator machine room, where space may be limited in the first place, the working-space mandate must be factored in very early in the design process lest an unthinkable amount of rework be necessary. Pits shall be maintained in a clean and dry condition. Other codes and standards interact with the NEC, and it is necessary to see how they all work together in order to create safe and compliant elevator designs/installations. The Code provides guidance through regulations to establish requirements. Mobile, AL 36606 USA Any other utilization equipment associated with the elevator The demand factor ranges from 1.00 for one elevator on a single feeder to 0.72 for 10 or more elevators on a single feeder. The fan should be on a dedicated circuit. . Elevator power disconnect (with utility feed marking) located in the machine room or other permitted location. Fuses: Verify that the correct size, type and capacity are installed. : inspecting; troubleshooting; observing; etc.) ^W i word/document.xml=nr]6Id=,_$j9-"Y.iGU\h_}. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. To safeguard the passengers and electrical equipment, ASME A17.12.8.2.3.2 requires the power source to the elevator control panel to shut down prior to the discharge of water from a sprinkler head. The two primary hazards are fire and electric shock or arc flash, although there are others. Personal protective equipment (PPE): Use appropriate PPE to protect body parts within the range of 3-16 in. Per the 2017 NEC, if the elevator is designated as an emergency system load, the disconnect must be protected by a surge protective device (SPD). And so the needs can be very different. However, this can vary depending on building conditions and exterior grade. It states an elevator is permitted to be run by an emergency or standby power system. Eazylift Albany LLC, 836 Troy Schenectady Rd, Latham, NY, Elevators This may be countered by providing good machine-room ventilation. Flexible cords and cables, or conductors grouped together and taped or corded, are permitted to be installed without a raceway. In these installations, it is best to design the elevator controller so the elevator controller SCCR is adequate for the available fault current. Similar provisions are attached to elevator-car heating and air-conditioning disconnecting means, and to other utilization equipment. The vast majority of equipment serving the elevator is located within this room (i.e., elevator controller). Section 620.62, Selective Coordination, is central to multi-elevator installations and must be closely observed. Section 620.43, Location of and Protection for Cables, provides that traveling cable supports are to be located so as to reduce the possibility of damage due to the cables coming in contact with the hoistway construction or equipment in the hoistway to a minimum. If elevators are supplied by the emergency, legally required standby or critical operation power systems, then selective coordination is required per the 2017 NEC in 700.32, 701.27 or 708.54. Granle is a licensed professional engineer with Sebesta Blomberg & Associates, Rochester, Minn. https://www.facebook.com/ElectricalConstructionMaintenanceMagazine, https://www.linkedin.com/company/electrical-construction-maintenance/, ABCs Construction Backlog Indicator Down to Start 2023, The Most Popular Code Quizzes of the Week from 2021, The 10 Most Popular Photo Galleries of 2021, Whats Wrong Here? Part VIII, Machine Rooms, Control Rooms, Machinery Spaces, and Control Spaces, states elevator and similar-installation driving machines, motor-generator sets, motor controllers and disconnecting means are to be installed in a room or space set aside for that purpose. Each of these performs a different function, and the wiring mandates vary accordingly. If your specifications require a vent at the top of the shaft for venting smoke, you must provide a key switch with a pilot light to control that vent. All equipment in a machine room-less design is installed within the elevator shaft or exterior compartment near the elevator shaft, including the elevator controller and the elevator disconnecting means. A section on branch circuits for car lighting, receptacles, ventilation, heating and air-conditioning contains a number of important provisions. 4.0 (2 Reviews) (2) CLAIMED . Moreover, it is necessary to consider future worker safety for an indefinite period. You need at least one 120VAC GFCI-protected receptacle at each location. Your Quick and Easy Elevator Code Checklist | Kings III First, the ATS signals the elevators that it's about to switch over to emergency power preferably 30 sec or more prior to switching, which allows the elevator controller to bring each elevator cab to the nearest landing and stop, thus protecting the motors and electrical system. DOCX 26 80 00 - Elevator Electrical Requirements - University of Illinois In hoistways not longer than 6 ft., these additional wiring methods are permitted: A sump or oil-recovery pump located in the pit is permitted to be cord connected. Additionally, ampacities of the individual conductors and flame-retardant properties of the overall cable are important factors. Thus, the traveling cable must be supported by a steel supporting member. This lighting and receptacle circuit is separate from the circuit serving the motor. For platform lifts and stairway chairlifts, the duty is intermittent. Conductors supplying a single motor are to have an ampacity not less than the percentage of motor nameplate current determined from Section 430.22(A) and (E). It is worth noting that these NEC terms, used throughout Article 620, have been chosen to correlate with A17.1-2007 usage. +90 (216) 348 4876, India Office One. A little more narrowly focused (yet of great consequence) is the ubiquitous NEC, which, in the National Fire Protection Association (NFPA)s venerable Handbook edition, devotes 18 double-column pages to electrical design and installation requirements for elevators, escalators and related equipment. The architect has a choice of either traction or hydraulic elevators. All of these options and special wiring can be challenging depending upon the location of the shunt trip circuit breaker as well as who has responsibility for providing these additional options. NEC Article 620 Part VI, Disconnecting Means and Control, is rather exacting. Liquid-tight flexible nonmetallic conduit, Flexible cords and cables, or conductors grouped together and taped or corded, are permitted without raceway, where they are part of listed equipment, a driving machine or a driving-machine brake, Flexible metal conduit, liquid-tight flexible metal or nonmetallic conduit, 3/8 in. Selective coordination is also required for multiple elevators per NEC 620.62. Traditionally, the electrical system design engineer has given little attention to the elevator controller. Hazards created by water, snow or condensation in the work area can cause slips, falls and accidental contact. The proposals resulted in adding new requirements in the 2017 NEC for: Marking the elevator controller short-circuit current rating (SCCR) by the elevator control-ler manufacturer. Elevator cab lights require emergency back-up power. Click to reveal Conductors supplying a single motor controller are to have an ampacity not less than the motor controller nameplate current rating plus all other connected loads. If a hydraulic elevator loses power because a heat detector goes off or for any other reason it could trap occupants for an unpleasant amount of time. They are to be located so as to be protected from physical damage, are to be of a flame-retardant type, and must be part of listed equipment, a driving machine or a driving-machine brake. While the definitions are straightforward, their deployment in real-life building projects involves enormous legal and moral implications, given the fact that we are carrying large numbers of people hundreds of feet above the earths surface on a daily basis. Of particular importance is the location of the disconnecting means so it can be found by an individual who may not be familiar with the installation. A separate branch circuit shall supply the hoistway pit lighting and receptacle (s). As mentioned, traditional installations of a traction or hydraulic elevator include a separate machine room. But by understanding how these items fit together and what purpose they serve, you can have a successful project. NEC Article 620 Part V, Traveling Cables, is driven by two major issues. It need not be exactly centered on the equipment, and working spaces of adjacent pieces of equipment may overlap. Furthermore, at least one 125-V, single-phase, 15- or 20-amp duplex receptacle is to be provided in each machine room or similar location. These conductors may be covered with suitable shielding for telephone, audio, video or higher-frequency communications circuits. The various items to consider and check when designing for elevator installations have many potential pitfalls. (A) tells us that the lighting and receptacle (s) for the pit must be on separate circuits. Here are 23 ways that both chapters and the national office can meet todays major challenge of making members feel valued, IAEIs Online Training allows you to learn at your own pace or live with an expert instructor, from the comfort of your laptop or PC. Many people use portable generators until power is restored. You are seeing this message for one of three reasons: You have reached your limit of free content. This may include wiring for signals, communication with the car, lighting, heating, air-conditioning and ventilation of the car or hoistway for fire-detecting systems and pit sump pumps. Other terms defined in NEC Article 620 are Control System, Motion Controller, Motor Controller, Operation Controller, Operating Device and Signal Device. With the elevator car at the bottom landing, it is the length of cable as measured from the point of suspension in the hoistway to the bottom of the loop. The hazards are external to the equipment enclosure since equipment SCCR testing and evaluation criteria for product standards are most often performed with the enclosure doors closed and latched, and the fault occurring external to the enclosure. PK ! This is because the material may contribute fuel to a fire that has originated elsewhere. or larger, not exceeding 6 ft. in length, are permitted between control panels and machine motors, machine brakes, motor-generator sets, disconnecting means and pumping motors and valves. Below is a summary of these new 2017 NEC sections: In order to comply with these requirements a chain of events must occur. In some cases, it may require a means to test the shunt trip operation or have one contact operate the shunt trip of more than one elevator. If you can illuminate the pit using lights that are "above the top of the pit" (whatever that . If this is not done and the available fault current exceeds the elevator controller SCCR, other solutions to reduce fault current must be reviewed or equipment changes and field evaluations may be needed. Three wiring categories within hoistways are allowed in addition, each with exceptions. z!0: - [Content_Types].xml ( n0EUb*>-RxV=QUAl"93dFk%Y?l}MGDV [emailprotected] or larger, not over 6 ft. in length. You need to Subscribe to continuing reading. endstream endobj startxref 836 Troy Schenectady Road Latham, NY 12110 . In all cases, the working space must permit at least a 90 opening of equipment doors or hinged panels. Even though Edison grasped the basic ideas of fusing and overcurrent protection, many hazards remained. NEC Article 620: Elevators, Part 2 - Elevator World, Inc. Many undertake trips in these devices two or more times daily in full confidence that they will survive an uneventful experience with a minute chance of disaster or even inconvenience. No provision is to be made to automatically restore power. In a time when increasing value is placed on even small amounts of real estate, elevator design must strive to configure, efficiently control and drive elements to whatever degree possible, and that is the thinking behind some alternate locations for these structures. A raceway that comes loose on the inside of a hoistway could catch on a moving car, causing immense damage and hazard to users. ELECTRIC PASSENGER & FREIGHT ELEVATORS ASME A17.1 2004 Electric Elevator Checklist 2004 Multi-car.doc Page 4 of 44 Page Completed for cars : - Last Updated: 8/1/05 Car Enclosure Electric 2.14 - Hydraulic 3.14 A17.1 (A17.2) COMMENTS CARS 1-6 Operating Control Devices ADA Requirements Within cars, these additional wiring methods are permitted: The following additional wiring methods are permitted on the car assembly in lengths not exceeding 6 ft.: Within machine rooms, these additional wiring methods are permitted: The following wiring methods are permitted on the counterweight assembly in lengths not to exceed 6 ft.: Having looked at NEC 2011 mandates for elevator and related equipment installations, we will cover wiring methods, overcurrent protection, grounding and other related NEC provisions in part two of this series , running in the April 2012 issue of ELEVATOR WORLD. Lights and convenience outlets in elevator pits shall be installed to comply with the requirements of CCR, Title 24, Part 3, Article 620. proved for elevator locations - car, hoistway, pit and a-chine roo equireents in Article odify the articles in Chap - ter For eaple, it is stated that the cross-sectional area Where voltages exceed 600, a sign reading DANGER HIGH VOLTAGE is required. It provides that where more than one driving-machine disconnecting means is supplied by a single feeder, the overcurrent protective devices in each disconnecting means are to be selectively coordinated with any other supply side overcurrent protective devices. The AHJ is saying that this is a violation of 620.23. The fan should be on a dedicated circuit. For example, it is stated that the cross-sectional area of the individual conductors in a wireway are not to exceed 50% of the interior cross-sectional area of the wireway. 2m9 `K]f*F gaR The code notes that elevator rails or other hoistway equipment are not to be used as the grounding conductor for lightning-protection systems. These may include: The author would like to recognize Jonathan Kennedy for his assistance in creating this article. The NEC rule specifies that the minimum size for paralleled conductors is 1/0 AWG, which is much too big for an elevator traveling cable. Flexible cords and cables in lengths not to exceed 6 ft. of a flame-retardant type and located to be protected from physical damage are permitted in machine rooms without being installed in a raceway. They are to be part of listed equipment, a driving machine or a driving-machine brake. Regardless of the number of elevators, only one smoke detector is required at each floor lobby, but it must be located within 21 ft of every elevator door. The drain or sump pump discharge shall be into the sanitary or storm drainage system through an indirect waste connection. It is conditionally provided that fiber-optic cables and conductors for operating devices, operation and motion control, power, signaling, fire alarm, lighting, heating and air-conditioning circuits of 600 V or less are permitted to be run in the same traveling cable or raceway system. Second, it must be configured so as to eliminate any chance of tangling or chafing against the inner surface of the hoistway or items mounted on it. This, however, can result in a dramatic increase in cost, space availability (lack thereof), and reduced efficiency. This strategy works to improve the flexibility of the traveling cable, but it is contrary to a general NEC rule concerning the paralleling of conductors, which is generally done in very large sizes to avoid unwieldy wire pulls and terminations. After reading this article, you should have learned about: The meanings of definitions for control room and control space versus machine room The purpose and specifications for working spaces Insulation types and minimum sizes of conductors Requirements for feeder and branch-circuit conductors Feeder demand factors for ele-vators. This equipment is restricted to that used in connection with the specific elevator, dumbwaiter, escalator, moving walk, platform lift or stairway chairlift. The reason the NEC CMP 12 added these requirements, as shown in the panel statements, directly relates to the concern that elevator controllers can be installed in locations where the available fault current can be high and the inspector may not be able to clearly determine the SCCR of the elevator controller unless it is marked on the equipment. High-rise buildings pose additional concerns. The circuit(s) for the lighting and receptacles must be dedicated to the elevator area only. +1-251-479-4514 | [emailprotected], Trkiye Office Dan Neeser is a Senior Field Application Engineer with Eatons Bussmann Division. Luminaires must be lensed or equipped with wire guards to protect the lamps. Dont troubleshoot unless you can keep your shoe/boot soles dry. Traction elevators are typically installed in a bank of elevators where fused switches, or circuit breakers in a panelboard are located in the machine room serving the bank of elevators. These must also be insulated for the maximum voltage applied to any conductor within the cable or raceway system. Fluid pressure in the cylinder raises and lowers the elevator cab. . These are the individual branch circuits required for car lighting, receptacles, auxiliary lighting and ventilation on each elevator car; individual branch circuits for machine-room and similar location lighting and receptacle; and branch circuits for hoistway pit lighting and receptacle(s). The lighting switch shall be located so as to be readily accessible from the pit access door. (e) Pit Maintenance. Get directions, reviews and information for Eazylift Albany LLC in Latham, NY. Thus, the need for door interlock functionality is recognized. If we fast forward more than 36 centuries, we see some important new developments in elevator technology. The thinking behind this requirement is that the injured worker could have severe hand burns and be unable to operate a conventional doorknob. Part of the reason that elevator usage is extraordinarily safe is that construction and maintenance are regulated by the wonderfully robust ASME A17.1 2007/CSA B44-07 Safety Code for Elevators and Escalators, which contains overall construction and maintenance requirements everything from seismic mandates to machine-room lighting. Elevator Pit Drain or Sump Pump | UpCodes NEC Guidelines on Commercial Garages | EC&M Instruments: Use category III multimeters and be familiar with their use and limitations. They must be in enclosures with doors or removable panels that can be locked in the closed position. Acceptable types of wire for this application are given in Table 400.4, which occurs in an earlier chapter and lists various types of elevator cable for lighting and control in both unclassified and hazardous locations. Traction elevators raise and lower the elevator cab with cables, a pulley system, and counter weights powered by a motor at the main drive wheel. of the sprinkler heads. Elevator motors are inherently intermittent duty. In Part One of this series (ELEVATOR WORLD, April 2012), we began an examination of National Electrical Code (NEC) 2011 mandates for elevators and related equipment installations. h-`7 employees shall not perform any work on equipment where there is a potential to come in contact with energized mechanical or electrical hazards until all sources of energy have been de-energized, grounded or guarded.. Additional requirements concern escape routes. Besides the initial determination requirement of paragraph (c) (1), the "host" employer must comply with the five (5) requirements of paragraph (c) (8) when engaging another employer (contractor) who will have employees in permit spaces under the control of the host employer. NEC 620.62 requires the elevator disconnecting means (fused switch or circuit breaker) to selectively coordinate with all supply-side overcurrent devices. When the elevator car is at the top landing, it is the length of cable as measured from the point of suspension on the car to the bottom of the loop. For elevators that regenerate power back into a power source unable to absorb the regenerative power under overhauling elevator load conditions, a means to absorb this power is to be provided. !>x=yy Bvv8?~e PK ! Because of this, several manufacturers offer an all-in-one shunt trip elevator disconnect switch that includes all the prewired accessories needed to comply with the various Code sections. This is typically accomplished via a shunt trip device. The basic rule for conductor fill of a metal wireway, as given in Article 376, is that the sum of the cross-sectional areas of all contained conductors at a cross section of a wireway is not to exceed 20% of the interior cross-sectional area of the wireway. Weight (passengers, freight, car and attendant machinery) may be fairly substantial, and speed is significant. It is noted that the article covers the installation of electrical equipment and wiring for elevators, dumbwaiters, escalators, moving walks, platform lifts and stairway chairlifts. While machine room-less designs have been commercially available for many years, their use may still be unknown to some AHJs. Cloudflare Ray ID: 7a2fbe9ebd7e2fe8 tC|[S9G?+uJP>&/TOy o PK ! +1-251-479-4514 | [emailprotected], Trkiye Office PDF C.1 General Requirements for All Elevator Installations You'll be responsible for specifying the items related to the fire alarm and some controls, as well as supplying lighting and power to the equipment room and elevator pit. PDF Electric Elevator Checklist Cover Page - Oregon Additionally, duty on elevator and dumbwaiter motors is rated as intermittent, whereas duty on escalator and moving-walk motors is considered continuous. It is of great importance that power to the various elevator functions can be quickly and reliably removed from the loads in case of emergency or for maintenance and troubleshooting. The Electrical Ups and Downs of Elevator Design | EC&M Similarly, underground wiring in mines is not NEC regulated, although other, non-mine wiring below ground (such as lighting in an underground traffic tunnel) is covered. Here, the National Electrical Safety Code has jurisdiction. Heating and air-conditioning equipment located on the car must not be in excess of 600 V. All live parts of electrical apparatuses are to be enclosed to protect workers and the public against accidental contact. Elevator Pit FC Requirements CE017 - 1 - AppendicesABC - Code Though I understand how someone might argue two. The disconnecting means is to be located adjacent to or an integral part of the motor controller. Overcurrent devices protecting these branch circuits are to be located in the machine room or similar location. He had been with Eaton (Cutler-Hammer and Bussmann) since 1993 and specializes in training on the design and application of overcurrent protective devices and equipment in electrical distribution systems in accordance with the National Electrical Code and equipment in accordance with the various product standards. Special conditions: Troubleshooting in wet, hot or cold conditions calls for extra caution. Follow the manufacturers instructions and precautions. This is important as the tradition of using only time-current curves for the analysis of overcurrent device operation is usually not sufficient since the time-current curves traditionally stop at 0.01 second (not time zero). Machine room-less elevator installations incorporate the elevator controller and often the primary disconnecting means in a convenient package that is located within the elevator shaft. If a smoke detector goes into alarm, it signals the elevator to go into Fire Recall Function, at which point the controller directs the elevator cab to travel to its pre-programmed designated landing, open its doors, and remain stopped there until the alarm clears. (B) Lighting Switch. NEC Article 620 covers elevators, dumbwaiters, escalators, moving walks, platform lifts and stairway chairlifts. (C) Duplex Receptacle. The locking capability is important so during maintenance, the equipment will not be inadvertently energized. Traveling cables are to be approved for hazardous locations and must comply with the appropriate sections for each hazardous-location class that covers use of flexible cords. In order to comply, the electrical system designer must determine the maximum available fault current at the elevator disconnecting means and assure the elevator disconnecting means overcurrent protective device will clear any overcurrent condition, up to the maximum available fault current, before any upstream overcurrent devices will operate. To achieve flexibility and endurance, traveling cable is more finely stranded and, where possible, separated into discrete conductors. PDF Q.When and where are GFCI's required by the NC Electrical Code It is further stipulated that internal voltages of power-conversion equipment and functionally associated equipment, and the operating voltages of wiring interconnecting the equipment, are permitted to be higher, provided that the equipment and wiring are listed for the higher voltages. Later in the 19th century, Thomas Edison and his associates built an electrical distribution system in Lower Manhattan. It employs specialists in Mobile, Alabama, and has technical and news correspondents around the world. It is important for the design engineer to coordinate with the architect to determine the elevator manufacturer basis of design to determine if and when additional power and lighting is required. Requirements for commercial garages per the National Electrical Code. This position paper is written to provide guidance to members whose employees are engaged in elevator-industry work that might expose them to arc-flash hazards, and to assist members in complying with applicable OSHA and National Fire Protection Association (NFPA) standards.